SHOULDER BELT ANCHORAGE SWITCH INSPECTION


  1. INSPECT HEIGHT ADJUSTABLE ANCHOR SWITCH (for LH Side)

    A01GKP0E03

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      3 (UL) - 4 (UP) UP Below 1 Ω
      2 (DW) - 4 (UP) UP 10 kΩ or higher
      2 (DW) - 3 (UL) DOWN Below 1 Ω
      3 (UL) - 4 (UP) DOWN 10 kΩ or higher

      If the result is not as specified, replace the height adjustable anchor switch.

  2. INSPECT HEIGHT ADJUSTABLE ANCHOR SWITCH (for RH Side)

    A01GKP0E04

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      2 (UP) - 3 (UL) UP Below 1 Ω
      2 (UP) - 4 (DW) UP 10 kΩ or higher
      3 (UL) - 4 (DW) DOWN Below 1 Ω
      2 (UP) - 3 (UL) DOWN 10 kΩ or higher

      If the result is not as specified, replace the height adjustable anchor switch.