INSPECT SHIFT SOLENOID VALVE (SLT, SL1, SL2)
| *a | Shift Solenoid Valve (SLT, SL1, SL2) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the value is not as specified, replace the shift solenoid valve (SLT, SL1, SL2).
Connect a positive (+) battery lead with a 21 W bulb to terminal 2 and a negative (-) battery lead to terminal 1 of the solenoid valve connector, and check the operation of the valve.
Note
When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.
| OK |
|---|
| The solenoid makes an operating sound. |
If the operation cannot be done as specified, replace the shift solenoid valve (SLT, SL1, SL2).
INSPECT SHIFT SOLENOID VALVE (DSL)
| *a | Shift Solenoid Valve (DSL) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the value is not as specified, replace the shift solenoid valve DSL.
Connect a positive (+) battery lead to the terminal of the solenoid connector, and a negative (-) battery lead to the solenoid body, and check the operation of the valve.
Note
When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.
| OK |
|---|
| The solenoid makes an operating sound. |
If the operation cannot be done as specified, replace the shift solenoid valve DSL.
INSPECT SHIFT SOLENOID VALVE (S4)
| *a | Shift Solenoid Valve (S4) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the value is not as specified, replace the shift solenoid valve S4.
Connect a positive (+) battery lead to the terminal of the solenoid connector, and a negative (-) battery lead to the solenoid body, and check the operation of the valve.
Note
When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.
| OK |
|---|
| The solenoid makes an operating sound. |
If the operation cannot be done as specified, replace the shift solenoid valve S4.