КОРПУС КЛАПАНОВ В СБОРЕ ПРОВЕРКА


  1. INSPECT SHIFT SOLENOID VALVE (SLT, SL1, SL2)


    1. A01CE1HE01
      Text in Illustration
      *a Shift Solenoid Valve (SLT, SL1, SL2)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω

      If the value is not as specified, replace the shift solenoid valve (SLT, SL1, SL2).

    2. Connect a positive (+) battery lead with a 21 W bulb to terminal 2 and a negative (-) battery lead to terminal 1 of the solenoid valve connector, and check the operation of the valve.

      Note

      When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.

      OK
      The solenoid makes an operating sound.

      If the operation cannot be done as specified, replace the shift solenoid valve (SLT, SL1, SL2).

  2. INSPECT SHIFT SOLENOID VALVE (DSL)


    1. A01CF9DE08
      Text in Illustration
      *a Shift Solenoid Valve (DSL)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Solenoid Terminal (DSL) - Solenoid Body (DSL) 20°C (68°F) 11 to 13 Ω

      If the value is not as specified, replace the shift solenoid valve DSL.

    2. Connect a positive (+) battery lead to the terminal of the solenoid connector, and a negative (-) battery lead to the solenoid body, and check the operation of the valve.

      Note

      When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.

      OK
      The solenoid makes an operating sound.

      If the operation cannot be done as specified, replace the shift solenoid valve DSL.

  3. INSPECT SHIFT SOLENOID VALVE (S4)


    1. A01CBR8E11
      Text in Illustration
      *a Shift Solenoid Valve (S4)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Solenoid Terminal (S4) - Solenoid Body (S4) 20°C (68°F) 11 to 15 Ω

      If the value is not as specified, replace the shift solenoid valve S4.

    2. Connect a positive (+) battery lead to the terminal of the solenoid connector, and a negative (-) battery lead to the solenoid body, and check the operation of the valve.

      Note

      When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.

      OK
      The solenoid makes an operating sound.

      If the operation cannot be done as specified, replace the shift solenoid valve S4.