СИСТЕМА АВТОМАТИЧЕСКОЙ ТРАНСМИССИИ, Diagnostic DTC:P2716

DTC Code DTC Name
P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

DESCRIPTION

The linear solenoid valve (SLT) controls the transmission line pressure for smooth transmission operation based on signals from the throttle position sensor and the vehicle speed sensor. The ECM adjusts the duty cycle of the SLT solenoid valve to control hydraulic line pressure coming from the primary regulator valve. Appropriate line pressure assures smooth shifting with varying engine outputs.

DTC No. DTC Detection Condition Trouble Area
P2716 Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detecting logic).
  • Open or short in shift solenoid valve SLT circuit

  • Transmission wire

  • Shift solenoid valve SLT

  • ECM

MONITOR DESCRIPTION

When an open or short in the linear solenoid valve (SLT) circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.

WIRING DIAGRAM

A01CF54E53

INSPECTION PROCEDURE

PROCEDURE


  1. INSPECT TRANSMISSION WIRE (SLT)


    1. A01CEIRE44

      Disconnect the transmission wire connector from the transaxle.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      2 (SLT+) - 7 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
    3. Measure the resistance according to the value(s) in the table below.

      Standard resistance (Check for short)
      Tester Connection Condition Specified Condition
      2 (SLT+) - Body ground Always 10 kΩ or higher
      7 (SLT-) - Body ground Always

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    1. A01CFRLE56

      Connect the transmission wire connector to the transaxle.

    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      D41-76 (SLT+) - D41-75 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
    4. Measure the resistance according to the value(s) in the table below.

      Standard resistance (Check for short)
      Tester Connection Condition Specified Condition
      D41-76 (SLT+) - Body ground Always 10 kΩ or higher
      D41-75 (SLT-) - Body ground Always

    NG
    OK
  3. INSPECT SHIFT SOLENOID VALVE SLT


    1. A01CGF5E43

      Remove the shift solenoid valve SLT.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    3. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

      OK
      The solenoid makes an operating sound.

    NG
    OK