ТОПЛИВНЫЙ НАСОС ПРОВЕРКА


  1. INSPECT FUEL PUMP


    1. Check the resistance.


      1. A01CDF3E01

        Using an ohmmeter, measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 - 2 Always

        0.2 to 3.0 Ω

        at 20°C (68°F)

        If the result is not as specified, replace the fuel pump.

    2. Check fuel pump operation.


      1. Apply battery voltage between terminals 1 and 2. Check that the pump operates.

        Note


        • This test must be done quickly (within 10 seconds) to prevent the coil from burning out.

        • Keep the fuel pump as far away from the battery as possible.

        • Always switch the voltage on and off on the battery side, not the fuel pump side.

        If the pump does not operate, replace the fuel pump.