ПОДОГРЕВАЕМЫЙ КИСЛОРОДНЫЙ ДАТЧИК УСТАНОВКА


  1. INSTALL HEATED OXYGEN SENSOR


    1. A01CDQWE01
      Text in Illustration
      *1

      Fulcrum Length

      30 mm

      Using SST, install the heated oxygen sensor.

      SST
      09224-00010
      Torque:
      without SST
      44 N*m  { 449 kgf*cm, 32 ft.*lbf }
      with SST
      39 N*m  { 398 kgf*cm, 29 ft.*lbf }

      Note


      • The "with SST" torque value is effective when using SST with a fulcrum length of 30 mm (1.18 in.).

      • The "with SST" torque value is effective when using a torque wrench with a fulcrum length of 260 mm (10.23 in.) Click here.

      • This torque value is effective when SST is parallel to the torque wrench.

    2. A01CD9G

      Connect the heated oxygen sensor connector.

  2. INSTALL FRONT EXHAUST PIPE ASSEMBLY


    1. A01CBMY

      Using a vernier caliper, measure the free length of the compression springs.

      Minimum length
      41.5 mm (1.64 in.)

      If the free length is less than the minimum, replace the compression spring.

    2. Fully insert a new gasket to the exhaust manifold converter sub-assembly.

    3. A01CFWCE15
      Text in Illustration
      *1 Exhaust Manifold Converter Sub-assembly
      *2 Gasket
      *3 Wooden Block

      Using a plastic hammer and wooden block, tap in the new gasket until its surface is flush with the exhaust manifold converter sub-assembly.

      Note


      • Be sure to install the gasket in the correct direction.

      • Do not reuse the gasket.

      • Do not damage the gasket.

      • Do not push in the gasket by using the exhaust pipe when connecting it.

    4. Install the front exhaust pipe assembly with the 2 bolts and 2 compression springs.

      Torque:
      43 N*m  { 440 kgf*cm, 32 ft.*lbf }
    5. Connect the oxygen sensor connector.

  3. INSPECT FOR EXHAUST GAS LEAK