TURN SIGNAL FLASHER ASSEMBLY ON-VEHICLE INSPECTION


  1. INSPECT TURN SIGNAL FLASHER ASSEMBLY


    1. Check the power source circuit and ground circuit.


      1. Disconnect the 3D, 3G and 3K connectors of the combination meter from the driver side junction block assembly.

      2. Measure the voltage and check the results in accordance with the value(s) in the table below.

        A0136J8E01
        Standard Voltage
        Tester Connection Condition Specified Condition
        3D-1 - Body ground Ignition switch ON 10 to 14 V
        3D-1 - Body ground Ignition switch OFF 0 V
        3G-2 - Body ground Always 10 to 14 V
      3. Measure the resistance and check the result in accordance with the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        3K-2 - Body ground Always Below 1 Ω
    2. Check the output operation signal.


      1. Connect the 3D, 3G and 3K connectors of the combination meter to the driver side junction block assembly.

      2. Measure the voltage and check the results in accordance with the value(s) in the table below.

        A0137IWE02
        Standard Voltage
        Tester Connection Condition Specified Condition
        3L-8 - Body ground Hazard switch OFF → ON 0 V → 10 to 14 V (60 to 120 times per minute)
        3L-8 - Body ground Turn signal switch (right turn) OFF → ON 0 V → 10 to 14 V (60 to 120 times per minute)
        3L-9 - Body ground Hazard switch OFF → ON 0 V → 10 to 14 V (60 to 120 times per minute)
        3L-9 - Body ground Turn signal switch (right turn) OFF → ON 0 V → 10 to 14 V (60 to 120 times per minute)
        3D-10 - Body ground Hazard switch OFF → ON 0 V → 10 to 14 V (60 to 120 times per minute)
        3D-10 - Body ground Turn signal switch (right turn) OFF → ON 0 V → 10 to 14 V (60 to 120 times per minute)
        3L-10 - Body ground Hazard switch OFF → ON 0 V → 10 to 14 V (60 to 120 times per minute)
        3L-10 - Body ground Turn signal switch (left turn) OFF → ON 0 V → 10 to 14 V (60 to 120 times per minute)
        3L-11 - Body ground Hazard switch OFF → ON 0 V → 10 to 14 V (60 to 120 times per minute)
        3L-11 - Body ground Turn signal switch (left turn) OFF → ON 0 V → 10 to 14 V (60 to 120 times per minute)
        3D-2 - Body ground Hazard switch OFF → ON 0 V → 10 to 14 V (60 to 120 times per minute)
        3D-2 - Body ground Turn signal switch (left turn) OFF → ON 0 V → 10 to 14 V (60 to 120 times per minute)
        3C-4 - Body ground Turn signal switch (left turn) OFF → ON 10 to 14 V → 0 V
        3C-9 - Body ground Turn signal switch (right turn) OFF → ON 10 to 14 V → 0 V
        C1-13 - Body ground Hazard switch OFF → ON 10 to 14 V → 0 V