STOP LIGHT SWITCH INSPECTION


  1. INSPECT STOP LIGHT SWITCH ASSEMBLY

    A0137VUE01

    1. Check the resistance.


      1. Using an ohmmeter, measure the resistance and check the results in accordance with the value(s) in the table below.

        Standard Resistance
        for 1KR-FE with Manual Transaxle
        Tester Connection Condition Specified Condition
        1 - 2 Switch pin released Below 1 Ω
        1 - 2 Switch pin pushed in 10 kΩ or higher

        If the result is not as specified, replace the stop light switch assembly.

        Standard Resistance
        for 1KR-FE with Multi-Mode Manual Transaxle, 2WZ-TV with Manual Transaxle
        Tester Connection Condition Specified Condition
        1 - 2 Switch pin released Below 1 Ω
        1 - 2 Switch pin pushed in 10 kΩ or higher
        3 - 4 Switch pin released 10 kΩ or higher
        3 - 4 Switch pin pushed in Below 1 Ω

        If the result is not as specified, replace the stop light switch assembly.