STOP LIGHT SWITCH INSTALLATION


  1. INSTALL STOP LIGHT SWITCH ASSEMBLY

    A0136Q3E02

    1. Insert the stop light switch assembly into the adjuster until it slightly touches the pedal sub-assembly.

      Note

      Do not depress the brake pedal.


      1. A01386UE02

        Make a quarter turn clockwise to install the stop light switch assembly.

        Note

        Do not depress the brake pedal.

        Tech Tips

        The turning torque for installing the stop light switch assembly is:

        Torque:
        1.5 N*m  { 15 kgf*cm, 13 in.*lbf, or less }
    2. Check the stop light switch clearance.

      Stop light switch clearance
      1.5 to 2.5 mm (0.059 to 0.098 in.)
    3. A0135S9

      Connect the stop light switch connector to the stop light switch assembly.

  2. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Torque:
    5.4 N*m  { 55 kgf*cm, 48 in.*lbf }