INSPECT ROOM LIGHT ASSEMBLY
Check the resistance.
Using an ohmmeter, measure the resistance and check the results in accordance with the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the room light assembly.
Check the light operation.
Connect the positive (+) battery lead to terminal 1 and the negative (-) battery lead to terminal 3, then check that the light comes on when the switch is in the DOOR position.
| Standard |
|---|
| Light comes on. |
If the light does not come on, replace the bulb.
Connect the positive (+) battery lead to terminal 2 and the negative (-) battery lead to terminal 3, then check that the light comes on when the switch is in the ON position.
| Standard |
|---|
| Light comes on. |
If the light does not come on, replace the bulb.