SPIRAL CABLE INSPECTION


  1. INSPECT SPIRAL CABLE


    1. If there are any defects as mentioned below, replace the spiral cable with a new one:


      • Scratches, cracks, dents or chips on the connector or the spiral cable.

    2. A0136ITE01

      Inspect the spiral cable.


      1. Measure the resistance according to the value(s) in the table below.

        Standard resistance
        Tester connection Condition Specified condition
        A1 (D+) - B1 (D+) Center Below 1 Ω
        2.5 rotations to the left
        2.5 rotations to the right
        A2 (D-) - B2 (D-) Center Below 1 Ω
        2.5 rotations to the left
        2.5 rotations to the right

        Note

        To avoid breaking the spiral cable, do not turn the spiral cable more than necessary.

        If the value is not within the specified range, replace the spiral cable.