CHECK REFRIGERANT PRESSURE USING MANIFOLD GAUGE SET
This is a method to specify trouble areas by using a manifold gauge set. Read the manifold gauge pressure under the following conditions.
Test conditions:
Engine has been warmed up.
All doors are fully open.
Switch A/C ON.
Blower switch is turned to ON.
Engine is running at 1,500 rpm.
Air inlet mode damper is set at recirculation.
Temperature control lever is in MAX. COLD position.
Air temperature at the air inlet is 20 to 35°C (68 to 95°F).
When the refrigerant volume is correct, the gauge reading indicates as follow:
| Low pressure side |
|---|
| 0.15 to 0.25 MPa (1.5 to 2.5 kgf/cm2) |
| High pressure side |
|---|
| 1.37 to 1.57 MPa (14 to 16 kgf/cm2) |
Tech Tips
Pressure varies under certain circumstances (outside air temperature, sunlight and wind).
When there is moisture in the refrigeration system:
| Symptoms | Probable Cause | Diagnosis | Corrective Actions |
|---|---|---|---|
| During operation, pressure on low pressure side cycles between normal and vacuum | Moisture in refrigeration system freezes at expansion valve orifice, causing temporary interuption of cycle However, when melted, returns to normal condition |
|
|
When cooling is insufficient:
| Symptoms | Probable Cause | Diagnosis | Corrective Actions |
|---|---|---|---|
|
Gas leakage from refrigeration system |
|
|
When the circulation of the refrigerant is poor:
| Symptoms | Probable Cause | Diagnosis | Corrective Action |
|---|---|---|---|
|
Refrigerant flow obstructed by dirt in condenser | Condenser clogged | Replace condenser |
When the refrigerant does not circulate:
| Symptoms | Probable Causes | Diagnosis | Corrective Actions |
|---|---|---|---|
|
|
Refrigerant does not circulate |
|
When the refrigerant is overcharged or cooling of condenser is insufficient:
| Symptoms | Probable Causes | Diagnosis | Corrective Actions |
|---|---|---|---|
| Pressure extremely high on both sides |
|
|
|
When there is air in the refrigeration system:
| Symptoms | Probable Causes | Diagnosis | Corrective Actions |
|---|---|---|---|
|
Air in refrigeration system |
|
|
When the expansion valve malfunctions:
| Symptoms | Probable Causes | Diagnosis | Corrective Actions |
|---|---|---|---|
|
Expansion valve malfunction |
|
Replace expansion valve |
When the compressor is defective:
| Symptoms | Probable Cause | Diagnosis | Corrective Actions |
|---|---|---|---|
|
Internal leakage in compressor |
|
Repair or replace compressor |
INSPECT IDLING SPEED
Warm up the engine.
Inspect idling speed when the these conditions are established.
Engine warm
Blower switch turned to ON
Temperature control lever is in MAX. COLD position
| Standard | ||||||
|---|---|---|---|---|---|---|
| for 1KR-FE | ||||||
|
||||||
| for 2WZ-TV | ||||||
|
If the idling speed is not as specified, check the idle control system.