DESCRIPTION
Refer to VSC Warning Light Remains ON Click here.
WIRING DIAGRAM
Refer to VSC Warning Light Remains ON Click here.
INSPECTION PROCEDURE
PROCEDURE
CHECK IF SKID CONTROL ECU CONNECTOR IS SECURELY CONNECTED
Check if the skid control ECU connector is securely connected.
| OK |
|---|
| The connector is securely connected. |
| NG |
|
CONNECT CONNECTOR TO ECU CORRECTLY |
| OK |
|
CHECK BATTERY
Check the battery voltage.
| Standard voltage |
|---|
| 11 to 14 V |
| NG |
|
CHECK OR REPLACE CHARGING SYSTEM OR BATTERY |
| OK |
|
CHECK VSC WARNING LIGHT
Turn the ignition switch to OFF and disconnect the skid control ECU connector.
Ground terminal VSCW of the skid control ECU.
Turn the ignition switch to ON.
Check the VSC warning light.
| OK | ||||||
|---|---|---|---|---|---|---|
|
Tech Tips
When the VSC warning light comes on, ground failure or open circuits in the brake actuator should be considered.
When the VSC warning light does not come on, opens in the wire harness among the combination meters or abnormalities in the meter circuit should be considered.
| NG |
|
CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - COMBINATION METER) Click here |
| OK |
|
INSPECT SKID CONTROL ECU (IG1 TERMINAL)
Disconnect the skid control ECU connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Standard voltage | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (IG1 CIRCUIT) |
| OK |
|
INSPECT SKID CONTROL ECU (GND TERMINAL)
Turn the ignition switch to OFF.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (GND CIRCUIT) |
| OK |
|
REPLACE BRAKE ACTUATOR ASSEMBLY Click here
CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - COMBINATION METER)
Turn the ignition switch to OFF.
Disconnect the skid control ECU connector and the combination meter connector.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
INSPECT IG2 FUSE
Remove the IG2 fuse from the instrument panel junction block.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE IG2 FUSE |
| OK |
|
CHECK HARNESS AND CONNECTOR (COMBINATION METER - BATTERY)
Disconnect the instrument panel junction block connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Standard voltage | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE COMBINATION METER ASSEMBLY Click here