BACK-UP LIGHT SWITCH INSPECTION


  1. INSPECT BACK-UP LIGHT SWITCH ASSEMBLY

    A0136PWE01

    1. Using an ohmmeter, measure the resistance between the terminals.

      Standard Resistance
      Condition Specified condition
      Released Below 1 Ω
      Pushed 10 kΩ or higher

      If the result is not as specified, replace the back-up light switch.