SELECT STROKE SENSOR INSTALLATION


  1. INSTALL SELECT STROKE SENSOR

    A01373GE01

    1. Apply MP grease to a new O-ring.

    2. Install the new O-ring onto the stroke sensor.

    3. Set the stroke sensor so that the sensor side and the actuator side sensor arms are in the positions shown in the illustration.

    4. A01362W

      Turn the stroke sensor clockwise and fix it with the 2 screws.

      Torque:
      2.0 N*m  { 20 kgf*cm, 18 in.*lbf }
    5. Connect the select stroke sensor connector.

  2. INSTALL BATTERY CLAMP SUB-ASSEMBLY

    A0135TUE03

    1. Install the battery clamp with the 3 bolts.

      Torque:
      Bolt A
      7.4 N*m  { 75 kgf*cm, 65 in.*lbf }
      Bolt B
      17 N*m  { 175 kgf*cm, 13 ft.*lbf }
    2. Engage the 2 wire harness clamps.

  3. INSTALL ENGINE ROOM RELAY BLOCK

    A0138XKE01

    1. Engage the claw and install the relay block.

    2. Install the 2 bolts.

      Torque:
      Bolt A
      5.4 N*m  { 55 kgf*cm, 48 in.*lbf }
      Bolt B
      8.4 N*m  { 85 kgf*cm, 74 in.*lbf }
  4. INSTALL BATTERY

    A0136YXE02

    1. Install the battery onto the battery clamp, as shown in the illustration.

      Note


      • The identification line should be seen after installing the battery.

      • The battery clamp should be in contact with the battery after the installation.

    2. A0136EQE01

      Install the battery clamp with the bolt.

      Torque:
      15 N*m  { 154 kgf*cm, 11 ft.*lbf }
    3. Connect the battery positive terminal with the nut.

      Torque:
      5.4 N*m  { 55 kgf*cm, 48 in.*lbf }
  5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Torque:
    5.4 N*m  { 55 kgf*cm, 48 in.*lbf }
  6. INITIALIZATION OF MULTI-MODE MANUAL TRANSMISSION ECU

    Click here

  7. LEARNING OF MULTI-MODE MANUAL TRANSMISSION SYSTEM

    Click here

  8. SYNCHRONIZATION POSITION CALIBRATION

    Click here