INSPECT GENERATOR REGULATOR ASSEMBLY
Using vernier calipers, measure the exposed brush length.
| Standard exposed length |
|---|
| 11.5 to 13.5 mm (0.45 to 0.53 in.) |
| Minimum exposed length |
|---|
| 6.5 mm (0.26 in.) |
If the exposed length is less than the minimum, replace the generator regulator.
INSPECT RECTIFIER HOLDER
Using an ohmmeter, check the continuity between terminals P1, P2, P3 and B, and terminals P1, P2, P3 and E.
| Standard |
|---|
| When the positive and negative poles between terminals P1, P2, P3 and B are exchanged, there is continuity in one way but no continuity in the other way. |
| When the positive and negative poles between terminals P1, P2, P3 and E are exchanged, there is continuity in one way but no continuity in the other way. |
If the continuity is not as specified, replace the generator.
INSPECT GENERATOR ROTOR ASSEMBLY
Check the generator rotor open circuit.
Using an ohmmeter, measure the resistance between the slip rings.
| Standard resistance |
|---|
| for Standard |
| 2.6 to 3.0 Ω at 20°C (68°F) |
| for Cold Area |
| 2.0 to 2.4 Ω at 20°C (68°F) |
If the resistance is not as specified, replace the generator.
Inspect slip rings.
Using vernier calipers, measure the slip ring diameter.
| Standard diameter |
|---|
| 16.1 to 16.3 mm (0.634 to 0.642 in.) |
| Minimum diameter |
|---|
| 15.9 mm (0.626 in.) |
If the diameter is less than minimum, replace the generator.