IGNITION SWITCH INSPECTION


  1. INSPECT IGNITION SWITCH


    1. A01392DE01

      Measure the switch resistance.

      Standard
      Switch Condition Tester Connection Specified Condition
      LOCK Between all terminals 10 kΩ or higher
      ACC 2 (AM1) - 4 (ACC) Below 1 Ω
      ON

      1 (IG1) - 2 (AM1)

      2 (AM1) - 4 (ACC)

      Below 1 Ω
      START

      1 (IG1) - 2 (AM1)

      2 (AM1) - 3 (ST1)

      Below 1 Ω

      If the result is not as specified, replace the switch.