AIR CONDITIONING SERVICE DATA

for 1KR-FE
Refrigerant charge volume 420 to 480 g (14.81 to 16.93 oz.)
Heater blower motor relay

3 - 4 : Below 1Ω

3 - 4: 10kΩ or higher(Apply battery voltage to terminals 1 and 2)

3 - 5 : 10kΩ or higher

3 - 5 : Below 1Ω(Apply battery voltage to terminals 1 and 2)

Magnet clutch relay

3 - 5 : 10kΩ or higher

3 - 5 : Below 1Ω(Apply battery voltage to terminals 1 and 2)

for 2WZ-TV
Refrigerant charge volume 470 to 530 g (16.58 to 18.69 oz.)
Heater blower motor relay

3 - 4 : Below 1Ω

3 - 4: 10kΩ or higher(Apply battery voltage to terminals 1 and 2)

3 - 5 : 10kΩ or higher

3 - 5 : Below 1Ω(Apply battery voltage to terminals 1 and 2)

Magnet clutch relay

3 - 5 : 10kΩ or higher

3 - 5 : Below 1Ω(Apply battery voltage to terminals 1 and 2)

PTC heater relay

3 - 5 : 10kΩ or higher

3 - 5 : Below 1Ω(Apply battery voltage to terminals 1 and 2)

PTC heater assembly Below 1Ω