| DTC Code | DTC Name |
|---|---|
| P2716 | Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) |
DESCRIPTION
The linear solenoid valve (SLT) controls the transmission line pressure for smooth transmission operation based on signals from the throttle position sensor and the vehicle speed sensor.
The ECM adjusts the duty cycle of the SLT solenoid valve to control hydraulic line pressure coming from the primary regulator valve. Appropriate line pressure assures smooth shifting with varying engine outputs.
(*): Duty Ratio
The duty ratio is the ratio of the period of continuity in one cycle.
For example, if A is the period of continuity in one cycle, and B is the period of non-continuity, then
Duty Ratio = A/(A + B) x 100 (%)
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P2716 | Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic). |
|
MONITOR DESCRIPTION
When an open or short in the linear solenoid valve (SLT) circuit is detected, the ECM interprets this as a fault.
The ECM will turn on the MIL and store the DTC.
INSPECTION PROCEDURE
PROCEDURE
INSPECT TRANSMISSION WIRE (SLT)
Disconnect the transmission wire connector from the transmission.
Measure the resistance according to the value(s) in the table below.
| Resistance | ||||
|---|---|---|---|---|
|
Measure the resistance according to the value(s) in the table below.
| Resistance (Check for short) | ||||||
|---|---|---|---|---|---|---|
|
| *a | Component without harness connected (Transmission Wire) |
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
Connect the transmission wire connector to the transmission.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Resistance | ||||
|---|---|---|---|---|
|
Measure the resistance according to the value(s) in the table below.
| Resistance (Check for short) | ||||||
|---|---|---|---|---|---|---|
|
| *a | Front view of wire harness connector (to ECM) |
INSPECT SHIFT SOLENOID VALVE SLT
Remove the shift solenoid valve (SLT).
Measure the resistance according to the value(s) in the table below.
| Resistance | ||||
|---|---|---|---|---|
|
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, and then check the movement of the valve.
| OK |
|---|
| The solenoid makes an operating sound. |
| *a | Component without harness connected (Shift Solenoid Valve SLT) |
REPLACE ECM
REPAIR OR REPLACE HARNESS OR CONNECTOR
REPLACE SHIFT SOLENOID VALVE SLT
REPAIR OR REPLACE TRANSMISSION WIRE