Click here
INSPECT RESISTANCE
Measure the resistance according to the value(s) in the table below.
Resistance
Terminal No (Terminal mark)
Oil temperature
Resistance
1(OT+)←→5(OT-)
10°C (50°F)
6.4 kΩ
1(OT+)←→5(OT-)
110°C (230°F)
0.2 kΩ