INSPECT SHIFT LOCK CONTROL UNIT ASSEMBLY
Disconnect the transmission control switch connector of shift lock control unit assembly.
Measure the resistance according to the value(s) in the table below when the shift lever is moved to each position.
| Shift position | Tester connection | Specified condition |
|---|---|---|
| D | 9 - 2 (NSSD - ATD) | Below 1 Ω |
| 3 | 10 kΩ or higher | |
| D | 9 - 3 (NSSD - AT3) | Below 1 Ω |
| 3 | 10 kΩ or higher |