КОРПУС КЛАПАНОВ В СБОРЕ ПРОВЕРКА


  1. INSPECT SHIFT SOLENOID VALVE SLT


    1. A01BF56E03
      Text in Illustration
      *a

      Component without harness connected

      (Shift Solenoid Valve SLT)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 2


      • Battery negative (-) → Terminal 1

      Valve moves and makes an operating noise

      If the result is not as specified, replace the shift solenoid valve.

  2. INSPECT SHIFT SOLENOID VALVE SL


    1. A01BE8BE01
      Text in Illustration
      *a

      Component without harness connected

      (Shift Solenoid Valve SL)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Shift solenoid valve SL connector terminal - Shift solenoid valve SL body 20°C (68°F) 11 to 15 Ω
    2. Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) → Shift solenoid valve SL connector


      • Battery negative (-) → Shift solenoid valve SL body

      Valve moves and makes an operating noise

      If the result is not as specified, replace the shift solenoid valve.

  3. INSPECT SHIFT SOLENOID VALVE S1 AND S2


    1. A01BAU6E01
      Text in Illustration
      *a

      Component without harness connected

      (Shift Solenoid Valve S1 and S2)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Shift solenoid valve connector terminal - Shift solenoid valve body 20°C (68°F) 11 to 15 Ω
    2. Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) → Shift solenoid valve connector


      • Battery negative (-) → Shift solenoid valve body

      Valve moves and makes an operating noise

      If the result is not as specified, replace the shift solenoid valve.