СИСТЕМА АВТОМАТИЧЕСКОЙ ТРАНСМИССИИ, Diagnostic DTC:P0973, P0974

Click here
Click here
DTC Code DTC Name
P0973 Shift Solenoid "A" Control Circuit Low (Shift Solenoid Valve S1)
P0974 Shift Solenoid "A" Control Circuit High (Shift Solenoid Valve S1)
Click here

DESCRIPTION

Shifting from 1st to 4th is performed in combination with the ON and OFF operation of shift solenoid valves S1 and S2, which are controlled by the ECM. If an open or short circuit occurs in either of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valve to allow the vehicle to be operated safely. Also, the ECM stops sending current to the open or short-circuited solenoid (Click here).

DTC Code DTC Detection Condition Trouble Area
P0973 ECM detects a short in the solenoid valve S1 circuit 2 times when solenoid valve S1 is operated (1-trip detection logic).
  • Short in shift solenoid valve S1 circuit

  • Shift solenoid valve S1

  • ECM

P0974 ECM detects an open in the solenoid valve S1 circuit 2 times when solenoid valve S1 is not operated (1-trip detection logic).
  • Open in shift solenoid valve S1 circuit

  • Shift solenoid valve S1

  • ECM

Click here

MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve S1 circuit. When there is an open or short circuit in either shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. When shift solenoid valve S1 is ON, if its resistance is 8 Ω or less, the ECM determines there is a short in the shift solenoid valve S1 circuit.

When shift solenoid valve S1 is OFF, if its resistance is 100 kΩ or higher, the ECM determines there is an open in the shift solenoid valve S1 circuit (Click here).

Click here

WIRING DIAGRAM

Click here

INSPECTION PROCEDURE

Tip:

Shift solenoid valve S1 is turned ON/OFF normally when the shift lever is in D.

ECM gear shift command 1st 2nd 3rd 4th
Shift solenoid valve S1 ON ON OFF OFF
Click here

PROCEDURE


  1. Click here

    INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE S1)


    1. A01BD99E02

      Disconnect the transmission wire connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      4 (S1) - Body ground 20°C (68°F) 11 to 15 Ω
      Table 1. Text in Illustration
      *a

      Component without harness connected

      (Transmission Wire)


  2. Click here

    CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    1. A01BFHCE34

      Disconnect the ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      D3-9 (S1) - Body ground 20°C (68°F) 11 to 15 Ω
      Table 2. Text in Illustration
      *a

      Rear view of wire harness connector

      (to ECM)


  3. Click here

    REPLACE ECM

  4. Click here

    INSPECT SHIFT SOLENOID VALVE S1


    1. A01BAU6E01

      Remove shift solenoid valve S1.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body 20°C (68°F) 11 to 15 Ω
    3. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) → Shift solenoid valve S1 connector

      • Battery negative (-) → Shift solenoid valve S1 body

      Valve moves and makes an operating noise
      Table 3. Text in Illustration
      *a

      Component without harness connected

      (Shift Solenoid Valve S1)


  5. Click here

    REPAIR OR REPLACE TRANSMISSION WIRE

  6. Click here

    REPAIR OR REPLACE HARNESS OR CONNECTOR

  7. Click here

    REPLACE SHIFT SOLENOID VALVE S1