    INSPECT PURGE VSV


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 26 to 30 Ω
      1 - Body ground Always 10 MΩ or higher
      2 - Body ground
      Tip:

      When measuring the coil resistance make sure that the surface temperature of the purge VSV is 20°C (68°F).

      If the result is not as specified, replace the purge VSV.

    2. Check the operation.


      1. A01BC64E06

        Check that air does not flow from port E to port F.

        Table 1. Text in Illustration
        *a Port E
        *b Port F
        A01BAZL Air
      2. Apply battery voltage across the terminals.

      3. A01BEKBE02

        Check that air flows from port E to port F.

        Table 2. Text in Illustration
        *a Port E
        *b Port F
        A01BAZL Air

        If the result is not as specified, replace the purge VSV.