ТРУБКА ВЕНТУРИ ПРОВЕРКА


  1. INSPECT VENTURI ASSEMBLY


    1. Resistance inspection. (Throttle control motor)


      1. A01BASB

        Using an ohmmeter, measure the resistance according to the value(s) in the table below.

        Standard resistance
        Terminals Temperature Resistance
        2 - 1, 3 at 20°C (68°F) 18 to 22 Ω
        5 - 4, 6 at 20°C (68°F) 18 to 22 Ω
    2. Continuity inspection. (Throttle valve switch)


      1. A01BF6Y

        Using an ohmmeter, measure the resistance according to the value(s) in the table below.

        Standard resistance
        Throttle valve Resistance
        Fully open Below 1 Ω
        Fully close 10 KΩ or higher