Click here

СИСТЕМА ECD MIL Circuit

Click here
Click here
DTC Code DTC Name
  MIL Circuit
Click here

DESCRIPTION

The Malfunction Indicator Lamp (MIL) is used to indicate the ECM's detection of a vehicle malfunction. The instrument panel J/B MET IGN fuse provides circuit power and the ECM provides the circuit ground that illuminates the MIL.

MIL operations should be checked visually:

The MIL should be illuminated when the ignition switch is first turned ON. If the MIL is always on or off, use the intelligent tester and follow the procedures below to determine the cause of the problem.

Click here

WIRING DIAGRAM

Click here

INSPECTION PROCEDURE

Click here

PROCEDURE


  1. Click here

    CHECK MIL


    1. A01BG58E02

      Turn the ignition switch ON.

      Result
      MIL Condition Proceed
      MIL is illuminated A
      MIL is not illuminated B

  2. Click here

    CLEAR DTC


    1. Connect the intelligent tester to the DLC3.

    2. Turn the ignition switch ON and push the intelligent tester main switch on.

    3. Read the DTC (Click here).

    4. Clear the DTC (Click here).

    5. Check that MIL is not illuminated.

      OK
      MIL is not illuminated.

  3. Click here

    REPAIR CIRCUIT INDICATED BY OUTPUT DTC

  4. Click here

    CHECK WIRE HARNESS (FOR SHORT IN WIRE CIRCUIT)


    1. A01BDBNE01

      Disconnect the B10 ECM connector.

    2. Turn the ignition switch ON.

    3. Check that MIL is not illuminated.

      OK
      MIL is not illuminated.

  5. Click here

    REPLACE ECM

  6. Click here

    CHECK HARNESS AND CONNECTOR (ECM - COMBINATION METER)


    1. A01BDBNE01

      Disconnect the B10 ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance (Check for short)
      Tester Connection Specified condition
      W (B10-5) - Body ground 10 kΩ or higher

  7. Click here

    CHECK FOR INTERMITTENT PROBLEMS

  8. Click here

    REPAIR OR REPLACE HARNESS OR CONNECTOR

  9. Click here

    INSPECT ECM (CHECK VOLTAGE)


    1. A01BCNHE18

      Turn the ignition switch ON.

    2. Measure the voltage according to the value(s) in the table below.

      Standard voltage
      Tester Connection Specified condition
      W (B10-5) - Body ground 9 to 14 V

  10. Click here

    REPLACE ECM

  11. Click here

    INSPECT COMBINATION METER (CHECK VOLTAGE)


    1. A01BHO7E04

      Disconnect the combination meter connector.

    2. Turn the ignition switch ON.

    3. Measure the voltage according to the value(s) in the table below.

      Standard voltage
      Tester Connection Specified condition
      EGW (H20-32) - Body ground 9 to 14 V

  12. Click here

    CHECK HARNESS AND CONNECTOR (ECM - COMBINATION METER)


    1. A01BB0ME02

      Disconnect the combination meter connector.

    2. Disconnect the B10 ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard resistance (Check for open)
      Tester Connection Specified condition
      EGW (H20-32) - W (B10-5) Below 1 Ω

  13. Click here

    CHECK FOR INTERMITTENT PROBLEMS

  14. Click here

    REPAIR OR REPLACE HARNESS OR CONNECTOR

  15. Click here

    INSPECT COMBINATION METER (CHECK VOLTAGE)


    1. A01BHO7E03

      Disconnect the combination meter connector.

    2. Turn the ignition switch ON.

    3. Measure the voltage according to the value(s) in the table below.

      Standard voltage
      Tester Connection Specified condition
      IG+ (H20-6) - Body ground 9 to 14 V

  16. Click here

    REPLACE COMBINATION METER

  17. Click here

    CHECK FUSE (MET IGN FUSE)


    1. A01BC34E01

      Remove the MET IGN fuse from the instrument panel J/B.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Specified Condition
      MET IGN fuse Below 1 Ω (Continuity)

  18. Click here

    CHECK HARNESS AND CONNECTOR (COMBINATION METER - MET IGN FUSE)


    1. A01BBPJE02

      Disconnect the combination meter connectors.

    2. Remove the MET IGN fuse from the instrument panel J/B.

    3. Measure the resistance according to the value(s) in the table below.

      Standard resistance (Check for open)
      Tester Connection Specified condition
      (MET IGN fuse terminal 1 of J/B) - IG+ (H20-6) Below 1 Ω

  19. Click here

    CHECK AND REPLACE HARNESS AND CONNECTOR (MET IGN FUSE - BATTERY)

  20. Click here

    REPLACE FUSE (MET IGN FUSE)

  21. Click here

    REPAIR OR REPLACE HARNESS OR CONNECTOR