SHIFT SOLENOID VALVE INSPECTION


  1. INSPECT SHIFT SOLENOID VALVE SL3


    1. A017EGEE90

      Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω

      If the value is not as specified, replace the shift solenoid valve.

    2. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

      OK
      The solenoid valve makes an operating sound.

      If the result is not as specified, replace the shift solenoid valve.

  2. INSPECT SHIFT SOLENOID VALVE SLT


    1. A017EGEE92

      Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω

      If the value is not as specified, replace the shift solenoid valve.

    2. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

      OK
      The solenoid valve makes an operating sound.

      If the result is not as specified, replace the shift solenoid valve.

  3. INSPECT SHIFT SOLENOID VALVE S4


    1. A017DXFE07

      Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      Solenoid Connector (S4) - Solenoid Body (S4) 20°C (68°F) 11 to 15 Ω

      If the value is not as specified, replace the shift solenoid valve.

    2. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

      OK
      The solenoid valve makes an operating sound.

      If the result is not as specified, replace the shift solenoid valve.

  4. INSPECT SHIFT SOLENOID VALVE SR


    1. A017FVDE07

      Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      Solenoid Connector (SR) - Solenoid Body (SR) 20°C (68°F) 11 to 15 Ω

      If the value is not as specified, replace the shift solenoid valve.

    2. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

      OK
      The solenoid valve makes an operating sound.

      If the result is not as specified, replace the shift solenoid valve.

  5. INSPECT SHIFT SOLENOID VALVE DSL


    1. A017E6UE11

      Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      Solenoid Connector (DSL) - Solenoid Body (DSL) 20°C (68°F) 11 to 15 Ω

      If the value is not as specified, replace the shift solenoid valve.

    2. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

      OK
      The solenoid valve makes an operating sound.

      If the result is not as specified, replace the shift solenoid valve.

  6. INSPECT SHIFT SOLENOID VALVE SL2


    1. A017EGEE89

      Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω

      If the value is not as specified, replace the shift solenoid valve.

    2. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

      OK
      The solenoid valve makes an operating sound.

      If the result is not as specified, replace the shift solenoid valve.

  7. INSPECT SHIFT SOLENOID VALVE SL1


    1. A017EGEE88

      Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω

      If the value is not as specified, replace the shift solenoid valve.

    2. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

      OK
      The solenoid valve makes an operating sound.

      If the result is not as specified, replace the shift solenoid valve.