| DTC Code | DTC Name |
|---|---|
| P0748 | Pressure Control Solenoid "A" Electrical (Shift Solenoid Valve SL1) |
DESCRIPTION
Shifting from 1st to 5th is performed in combination with "ON" and "OFF" operation of the shift solenoid valves SL1, SL2, SL3, S4 and SR which are controlled by the ECM. If an open or short circuit occurs in either of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly (Fail safe function).
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0748 | The ECM checks for an open or short in the shift solenoid valve SL1 circuit while driving and shift gears. (1-trip detection logic)
|
|
MONITOR DESCRIPTION
The ECM commands gear shifts by turning the shift solenoid valves "ON/OFF". When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem and illuminates the MIL and stores the DTC. And the ECM performs the fail-safe function and turns the other normal shift solenoid valves "ON/OFF" (In case of an open or short circuit, the ECM stops sending current to the circuit.) (Click here).
INSPECTION PROCEDURE
PROCEDURE
INSPECT TRANSMISSION WIRE (SL1)
Disconnect the transmission wire connector from the transaxle.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
Measure the resistance according to the value(s) in the table below.
| Standard resistance (Check for short) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
Connect the transmission wire connector to the transaxle.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
Measure the resistance according to the value(s) in the table below.
| Standard resistance (Check for short) | |||||||
|---|---|---|---|---|---|---|---|
|
INSPECT SHIFT SOLENOID VALVE (SL1)
Remove the shift solenoid valve SL1.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
| OK |
|---|
| The solenoid makes an operating sound. |
REPAIR OR REPLACE TRANSMISSION WIREClick here
REPLACE ECM (for 2GR-FE)Click here
REPAIR OR REPLACE HARNESS OR CONNECTOR
REPLACE SHIFT SOLENOID VALVE (SL1)Click here