CANISTER REMOVAL


  1. REMOVE COOL AIR INTAKE DUCT SEAL


    1. A017CN1

      Remove the 11 clips and cool air intake duct seal.

  2. REMOVE NO. 2 AIR CLEANER INLET


    1. A017D82

      Disconnect the 2 vacuum switching valve clamps.

    2. Disconnect the 2 vacuum hoses.

    3. Remove the 2 bolts and No. 2 air cleaner inlet.

  3. REMOVE AIR CLEANER CAP SUB-ASSEMBLY


    1. A017BB9

      Disconnect the 3 vacuum hoses.

    2. A017EZ4

      Loosen the No. 1 air cleaner hose clamp.

    3. Disconnect the hose clamps and No. 2 ventilation hose.

    4. Disconnect the mass air flow meter connector.

    5. A017FXX

      Release the 2 clips, and remove the 2 bolts.

    6. Remove the air cleaner cap sub-assembly and air cleaner filter element.

  4. REMOVE AIR CLEANER CASE SUB-ASSEMBLY


    1. A017BI0

      Remove the 3 bolts, disconnect the hose and the connector, and remove the air cleaner case sub-assembly.

  5. REMOVE CHARCOAL CANISTER ASSEMBLY (for LHD)


    1. A017CNW

      Disconnect the 2 hoses.

    2. A017EV1

      Remove the 2 bolts and canister.

  6. REMOVE CHARCOAL CANISTER ASSEMBLY (for RHD)


    1. A017D62

      Disconnect the 2 hoses.

    2. A017BEU

      Remove the canister from the bracket.