| DTC Code | DTC Name |
|---|---|
| B1411/11 | Room Temperature Sensor Circuit |
DESCRIPTION
The room temperature sensor is installed in the instrument panel to detect the room temperature and control the heater and air conditioning AUTO mode. The resistance of the room temperature sensor changes in accordance with the room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier applies a voltage (5 V) to the room temperature sensor and reads voltage changes as changes in the resistance of the room temperature sensor.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1411/11 | Open or short in room temperature sensor circuit |
|
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
READ VALUE USING INTELLIGENT TESTER (ROOM TEMP)
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch on.
Select the item below in the Data List, and read the value displayed on the intelligent tester.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Room Temp | Room temperature sensor / Min.: -6.5°C (20.3°F) Max.: 57.25°C (135.05°F) |
Actual room temperature is displayed | Open circuit: -6.5°C (20.3°F) Short circuit: 57.25°C (135.05°F) |
| OK |
|---|
| The display is as specified in the normal condition column. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| B |
|
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| C |
|
REPLACE AIR CONDITIONING AMPLIFIER Click here |
| A |
|
INSPECT ROOM TEMPERATURE SENSOR
Remove the room temperature sensor (for front) Click here.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
When measuring, the sensor temperature must be the same as the ambient temperature.
Tech Tips
As the temperature increases, the resistance decreases (see the graph).
| NG |
|
REPLACE ROOM TEMPERATURE SENSOR Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)
Disconnect the D23 sensor connector.
Disconnect the D33 amplifier connector.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE AIR CONDITIONING AMPLIFIER Click here