READ DATA LIST
Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators, and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester on.
Read the Data List by following the prompts on the tester.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Room Temperature sensor (Room Temp) |
Room temperature sensor / Min.: -6.5°C (20.3°F) Max.: 57.25°C (135.05°F) |
Actual cabin temperature is displayed | - |
| Ambient Temp Sensor (Ambi Temp Sens) |
Ambient temperature sensor / Min.: -23.3°C (-9.94°F) Max.: 65.94°C (150.71°F) |
Actual ambient temperature is displayed | - |
| Adjusted Ambient Temp (Ambi Temp) |
Adjusted ambient temperature / Min.: -30.8°C (-23.44°F) Max.: 50.8°C (123.44°F) |
- | - |
| Solar Sensor (D side) (Solar Sens-D) |
Driver side solar sensor / Min.: 0, Max.: 255 |
Driver side solar sensor value increases as brightness increases | - |
| Solar Sensor (P side) (Solar Sens-P) |
Passenger side solar sensor / Min.: 0, Max.: 255 |
Front passenger side solar sensor value increases as brightness increases | - |
| Engine Coolant Temp (Coolant Temp) |
Engine coolant temperature sensor / Min.: 1.3°C (34.34°F) Max.: 90.55°C (194.99°F) |
Actual engine coolant temperature is displayed | - |
| Set Temperature (D side) (Set Temp-D) |
Driver side set temperature / Min.: 0°C (32°F) Max.: 30°C (86°F) |
Driver side actual set temperature is displayed | - |
| Set Temperature (P side) (Set Temp-P) |
Passenger side set temperature / Min.: 0°C (32°F) Max.: 30°C (86°F) |
Front passenger side actual set temperature is displayed | - |
| Blower Motor Speed Level (Blower Level) |
Blower motor speed level / Min.: 0, Max.: 31 |
Increases in range between 0 and 31 as blower motor speed increases | - |
| Air Mix Servo Targ Pulse (D) (Air Mix Pulse-D) |
Driver side air mix control servo motor target pulse / Min.: 0, Max.: 255 |
|
- |
| Air Mix Servo Targ Pulse (P) (Air Mix Pulse-P) |
Passenger side air mix control servo motor target pulse / Min.: 0, Max.: 255 |
|
- |
| Air Outlet Servo Pulse (D) (Air Out Pulse-D) |
Driver side air outlet control servo motor target / Min.: 0, Max.: 255 |
FACE: 8 (pulse) B/L: 30 (pulse) FOOT: 67 (pulse) FOOT/DEF: 80 (pulse) DEF: 97 (pulse) |
- |
| Air Inlet Damper Targ Pulse (A/I Damp Targ Pls) |
Air inlet damper target pulse / Min.: 0, Max.: 255 |
RECIRCULATION: 7 (pulse) FRESH: 28 (pulse) |
- |
| Evaporator Fin Thermistor (Evap Fin Temp) |
Evaporator temperature sensor / Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature is displayed | - |
| Evaporator Target Temp (Evap Tag Temp) |
Evaporator target temperature / Min.: -327.68°C (-557.82°F) Max.: 327.68°C (621.81°F) |
Evaporator target temperature displayed | - |
| Regulator Pressure Sensor (Reg Press Sens) |
Regulator pressure sensor / Min.:-0.45668 MPaG Max.: 3.29437 MPaG |
Actual regulator pressure is displayed | - |
| Regulator Control Current (Reg Ctrl Currnt) |
Regulator control current / Min.: 0 A Max.: 0.997 A |
Value changes between 0 A and 0.997 A in accordance with compressor operation | - |
| Room Temp Sensor (Rear) (Rear Room Temp) |
Rear room temperature sensor / Min.: -6.5°C (20.3°F) Max.: 57.25°C (135.05°F) |
Actual rear cabin temperature is displayed | - |
| Set Temperature (Rear) (Set Temp Rear) |
Rear set temperature / Min.: 0 Max.: 255 |
Actual rear set temperature is displayed | - |
| Blower Motor Level (Rear) (Blower Level-R) |
Rear blower motor speed level / Min.; 0, Max.: 31 |
Increases in range between 0 and 31 as rear blower motor speed increases | - |
| Air Outlet Servo Pulse (R) (Air Out Pulse-R) |
Rear air outlet control servo motor target pulse / Min.: 0, Max.: 255 |
Rr FACE: 83 (pulse) Rr B/L: 38 (pulse) Rr FOOT: 7 (pulse) |
- |
| Air Mix Servo Targ Pulse (R) (Air Mix Pulse-R) |
Rear air mix control servo motor target pulse / Min.: 0, Max.: 255 |
|
- |
| Ambient Temp Sens (Rear) (R-Ambi Temp Sen) |
Rear Evaporator temperature sensor / Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature is displayed | - |
| Flow Sensor (Flow Sens) |
A/C flow sensor / Min.: 0V, Max.: 5 V | Ignition switch on (IG): 0.3 to 4.7 V | A/C flow sensor is malfunctioning when a constant value below 0.3 V or higher than 4.7 V is displayed continuously for more than 4 seconds. |
| A/C Cutoff Signal (A/C Cutoff) |
A/C control cutoff signal / OFF or ON |
A/C switch on: OFF A/C switch off: ON |
- |
| Number of Trouble Codes (#Codes) |
Number of trouble codes / Min.: 0, Max.: 255 |
Number of DTCs displayed | - |
PERFORM ACTIVE TEST
Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester on.
Perform the Active Test by following the prompts on the tester.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower motor | Min.: 0, Max.: 31 | - |
| Magnetic Clutch Relay | Magnetic clutch relay | OFF, ON | - |
| Defogger Relay (Rear) | Defogger relay (Rear) | OFF, ON | - |
| Mirror Heater Relay | Mirror Heater | OFF, ON | - |
| Deicer Relay (Front) | Front window deicer | OFF, ON | - |
| Heater Active Level | Heater active level | Min.: 0, Max.: 3 | - |
| Air Mix Servo Targ Pulse (D) | Air mix servo motor pulse (D side) |
|
- |
| Air Mix Servo Targ Pulse (P) | Air mix servo motor pulse (P side) |
|
- |
| Air Outlet Servo Targ Pulse (D) | Air outlet servo motor pulse (D side) | Min.: 8, Max.: 97 | - |
| Air Inlet Damper Targ Pulse | Air inlet damper target pulse | Min.: 7, Max.: 28 | - |
| Rear Blower Motor | Rear blower motor | Min.: 0, Max.: 31 | - |
| Rear Air Mix Servo Targ Pulse | Rear air mix control servo motor pulse | Min.: 9, Max.: 54 | - |