VEHICLE STABILITY CONTROL SYSTEM Skid Control Buzzer Circuit

DESCRIPTION

The skid control buzzer sounds during VSC operation.

WIRING DIAGRAM

A017CIFE02

INSPECTION PROCEDURE

Note

When replacing the brake actuator assembly, perform zero point calibration Click here.

PROCEDURE


  1. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (SKID CONTROL BUZZER)


    1. Connect the intelligent tester to the DLC3.

    2. Start the engine.

    3. Select the Active Test mode on the intelligent tester Click here.

      ABS / VSC / TRC:
      Tester Display Test Part Control Range Diagnostic Note
      Buzzer Skid control buzzer Buzzer ON / OFF Buzzer can be heard
    4. Check that the buzzer sounds/stops when turning the skid control buzzer on/off by using the intelligent tester.

      Result
      Result Proceed to
      Buzzer does not sound or sounds constantly A
      Buzzer sounds/stops B

      Tech Tips

      If troubleshooting has been carried out according to the Problem Symptoms Table, refer back to the table and proceed to the next step Click here.


    B
    A
  2. INSPECT SKID CONTROL BUZZER (POWER SOURCE TERMINAL)


    1. A017DCZE06

      Turn the ignition switch off.

    2. Disconnect the skid control buzzer connector.

    3. Turn the ignition switch on (IG).

    4. Measure the voltage according to the value(s) in the table below.

      Standard voltage
      Tester Connection Switch Condition Specified Condition
      A17-2 - Body ground Ignition switch on (IG) 11 to 14 V

    NG
    OK
  3. INSPECT SKID CONTROL BUZZER


    1. A017BLPE01

      Turn the ignition switch off.

    2. Apply battery negative voltage to terminal 1, and battery positive voltage to terminal 2 of the skid control buzzer, and then check that the buzzer sounds.

      OK
      The skid control buzzer sounds.

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - SKID CONTROL BUZZER)


    1. A017EOZE03

      Disconnect the skid control ECU connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      A24-21 (BZ) - A17-1 Always Below 1 Ω
      A24-21 (BZ) - Body ground Always 10 kΩ or higher

      Tech Tips

      If troubleshooting has been carried out according to the Problem Symptoms Table, refer back to the table and proceed to the next step before replacing the part Click here.


    NG
    OK