AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) PTC Heater Circuit

DESCRIPTION

PTC heater relays are closed in accordance with signals from the air conditioning amplifier and power is supplied to the PTC heater installed on the radiator heater unit.

WIRING DIAGRAM

A017CEKE15

INSPECTION PROCEDURE

PROCEDURE


  1. INSPECT FUSE (PTC NO. 1, PTC NO. 2, PTC NO. 3)


    1. Remove the PTC NO. 1, PTC NO. 2 and PTC NO. 3 fuses from the engine room No. 2 relay block.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      PTC NO. 1 Always Below 1Ω
      PTC NO. 2 Always Below 1Ω
      PTC NO. 2 Always Below 1Ω

    NG
    OK
  2. INSPECT PTC HEATER RELAY


    1. A017EO0E24

      Remove the PTC HTR1, PTC HTR2 and PTC HTR3 relays from the engine room No. 2 relay block.

    2. Measure the resistance of the relays.

      Standard resistance
      Tester Connection Condition Specified Condition
      3 - 5 when battery voltage is not applied to terminals 1 and 2 10 kΩ or higher
      3 - 5 when battery voltage is applied to terminals 1 and 2 Below 1 Ω

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (PTC HEATER RELAY - BODY GROUND)


    1. A017ENPE17

      Remove the PTC HTR1, PTC HTR2 and PTC HTR3 relays from the engine room No. 2 relay block.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      PTC HTR1 heater relay terminal 2 - Body ground Always Below 1 Ω
      PTC HTR2 heater relay terminal 2 - Body ground Always Below 1 Ω
      PTC HTR3 heater relay terminal 2 - Body ground Always Below 1 Ω

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - PTC HEATER RELAY)


    1. A017ENPE18

      Remove the PTC HTR1, PTC HTR2 and PTC HTR3 relays from the engine room No. 2 relay block.

    2. Turn the ignition switch on (IG).

    3. When the PTC heater operating conditions are met (engine at idling speed or faster, ambient temperature is 10°C (50°F) or less, engine coolant temperature is 65°C (149°F) or less, set temperature switch is set to MAX HOT), turn the blower switch to the Lo setting.

    4. Measure the voltage according to the value(s) in the table below.

      Standard voltage
      Tester Connection Condition Specified Condition
      PTC HTR1 heater relay terminal 1 - Body ground Always 11 to 14 V
      PTC HTR2 heater relay terminal 1 - Body ground Always 11 to 14 V
      PTC HTR3 heater relay terminal 1 - Body ground Always 11 to 14 V

    NG
    OK
  5. CHECK HARNESS AND CONNECTOR (BATTERY - PTC HEATER RELAY)


    1. A017ENPE19

      Remove the PTC HTR1, PTC HTR2 and PTC HTR3 relays from the engine room No. 2 relay block.

    2. Measure the voltage according to the value(s) in the table below.

      Standard voltage
      Tester Connection Condition Specified Condition
      PTC HTR1 heater relay terminal 5 - Body ground Always 11 to 14 V
      PTC HTR2 heater relay terminal 5 - Body ground Always 11 to 14 V
      PTC HTR3 heater relay terminal 5 - Body ground Always 11 to 14 V

    NG
    OK
  6. CHECK HARNESS AND CONNECTOR (PTC HEATER RELAY - PTC HEATER)


    1. A017BYZE02

      Remove the PTC HTR1, PTC HTR2 and PTC HTR3 relays from the engine room No. 2 relay block.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      PTC HTR1 heater relay terminal 3 - D40-2 (B) Always Below 1 Ω
      PTC HTR2 heater relay terminal 3 - D40-3 (B) Always Below 1 Ω
      PTC HTR3 heater relay terminal 3 - D40-1 (B) Always Below 1 Ω

    NG
    OK
  7. CHECK AIR CONDITIONING AMPLIFIER


    1. A017GAQE21

      Remove the air conditioning amplifier with its connectors still connected.

    2. Turn the ignition switch on (IG).

    3. When the PTC heater operating conditions are met (engine at idling speed or faster, ambient temperature is 10°C (50°F) or less, engine coolant temperature is 65°C (149°F) or less, set temperature switch is set to MAX HOT), turn the blower switch to the Lo setting.

    4. Measure the voltage according to the value(s) in the table below.

      Standard voltage
      Tester Connection Condition Specified Condition
      D33-3 (PTC1) - Body ground Always 11 to 14 V
      D33-22 (PTC2) - Body ground Always 11 to 14 V
      D33-4 (PTC3) - Body ground Always 11 to 14 V

    NG
    OK
  8. REPLACE PTC HEATER


    1. Replace the PTC heater Click here


    NEXT
  9. CHECK PTC HEATER (OPERATION)


    1. Operate the PTC heater to check that functions properly.

      OK
      PTC heater function operates normally.

    NG
    OK