DESCRIPTION
The CAN main bus line and DLC3 sub bus line may have a disconnection when the resistance between terminals 6 (CANH) and 14 (CANL) of the DLC3 is more than 69 Ω.
| Symptom | Trouble Area |
|---|---|
| Resistance between terminals 6 (CANH) and 14 (CANL) of the DLC3 is more than 69 Ω. |
|
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
CHECK DLC3
Measure the resistance according to the value(s) in the table below.
| Result | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
When the measured value is 132 Ω or higher and air conditioning control functions (cooling, heating, and dehumidification) do not operate normally, there may be a fault other than a disconnection in the DLC3 sub bus line. For that reason, troubleshooting should be performed again from "HOW TO PROCEED WITH TROUBLESHOOTING Click here" after repairing the trouble area.
| B |
|
REPAIR OR REPLACE DLC3 SUB BUS LINE OR CONNECTOR (CAN-H, CAN-L) |
| A |
|
INSPECT CAN J/C
Disconnect the CAN main bus line connector (H4) from the CAN J/C.
Note
Before disconnecting the connector, make a note of where it is connected.
Reconnect the connector to its original position.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE CAN J/C |
| OK |
|
INSPECT ECM
Disconnect the ECM connector (B7). (for 1TR-FE, 2TR-FE, 2KD-FTV)
Disconnect the ECM connector (B47). (for 1KD-FTV)
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
| for 1TR-FE, 2TR-FE | ||||||
|
||||||
| for 1KD-FTV | ||||||
|
||||||
| for 2KD-FTV | ||||||
|
| NG |
|
REPLACE ECM |
| OK |
|
REPAIR OR REPLACE CAN MAIN BUS LINE OR CONNECTOR (CAN J/C - ECM)