DESCRIPTION
Measure the resistance from the DLC3 before checking the CAN bus lines to troubleshoot the CAN communication system.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
CHECK CAN BUS WIRE (MAIN BUS LINE FOR DISCONNECTION, BUS LINES FOR SHORT CIRCUIT)
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG-A |
|
OPEN IN CAN MAIN BUS LINE |
| NG-B |
|
SHORT IN CAN BUS LINES |
| OK |
|
CHECK CAN BUS LINE FOR SHORT TO B+
Measure the resistance according to the value(s) in the table below.
| Standard resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
NG: Short to B+ in CAN Bus Line Click here
| NG |
|
SHORT TO B+ IN CAN BUS LINE |
| OK |
|
CHECK CAN BUS LINE FOR SHORT TO GND
Measure the resistance according to the value(s) in the table below.
| Standard resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
OK: HOW TO PROCEED WITH TROUBLESHOOTING Click here
NG: Short to GND in CAN Bus Line Click here
| NG |
|
SHORT TO GND IN CAN BUS LINE |
| OK |
|
GO TO "HOW TO PROCEED WITH TROUBLESHOOTING"