POWER SLIDE DOOR CONTROL SWITCH INSPECTION


  1. INSPECT POWER SLIDE DOOR CONTROL SWITCH


    1. A01BD0BE01

      Check the resistance.


      1. Using an ohmmeter, measure the resistance and check the results in accordance with the value(s) in the table below.

        Standard resistance
        Tester Connection Condition Specified Condition
        3 - 4 Switch released 10 kΩ or higher
        3 - 4 Switch pressed in Below 1 Ω

        If the result is not as specified, replace the power slide door control switch.

    2. Check the illumination operation.


      1. Apply battery voltage to the power slide door control switch and check that the illumination comes on.

        Standard
        Measurement Condition Specified Condition

        Battery positive (+) → Terminal 2

        Battery negative (-) → Terminal 1

        Illumination comes on

        If the result is not as specified, replace the power slide door control switch.