SLIDE DOOR CLOSER SYSTEM Slide Door Closer Relay Power Source Circuit

DESCRIPTION

Power is supplied from the door control relay to the slide door closer relay.

WIRING DIAGRAM

A01BCYTE01

INSPECTION PROCEDURE

PROCEDURE


  1. CHECK WIRE HARNESS (SLIDE DOOR CLOSER RELAY - BATTERY AND BODY GROUND)


    1. A01BGM0E01

      Disconnect the slide door closer relay connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      7 (GND) - Body ground Always Below 1 Ω
    3. Measure the voltage according to the value(s) in the table below.

      Standard voltage
      Tester Connection Condition Specified Condition
      5 (+B) - Body ground Slide door OPEN → Halfway position 0 V → 10 to 14 V

    NG
    OK
  2. INSPECT SLIDE DOOR CONTROL JUNCTIONFEMALE


    1. A01BAYGE01

      Inspect the slide door control junctionfemale.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      A - 1 Always Below 1 Ω
      E - 2 Always Below 1 Ω

    NG
    OK
  3. INSPECT SLIDE DOOR CONTROL JUNCTIONMALE


    1. A01BECAE01

      Inspect the slide door control junctionmale.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      A - 1 Always Below 1 Ω
      E - 4 Always Below 1 Ω

    NG
    OK
  4. CHECK WIRE HARNESS (SLIDE DOOR CLOSER RELAY - DOOR CONTROL RELAY)


    1. A01BCGYE03

      Disconnect the B33 (M2) and slide door lock assembly connectors.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      LH side
      Tester Connection Condition Specified Condition
      B33-4 - 7 Always Below 1 Ω
      B33-5 - 5 Always 10 kΩ or higher
      RH side
      Tester Connection Condition Specified Condition
      M2-4 - 7 Always Below 1 Ω
      M2-5 - 5 Always 10 kΩ or higher

    NG
    OK