DESCRIPTION
Power is supplied from the door control relay to the slide door closer relay.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
CHECK WIRE HARNESS (SLIDE DOOR CLOSER RELAY - BATTERY AND BODY GROUND)
Disconnect the slide door closer relay connector.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
Measure the voltage according to the value(s) in the table below.
| Standard voltage | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
INSPECT SLIDE DOOR CONTROL JUNCTIONFEMALE Click here |
| OK |
|
REPLACE SLIDE DOOR CLOSER RELAY
INSPECT SLIDE DOOR CONTROL JUNCTIONFEMALE
Inspect the slide door control junctionfemale.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE SLIDE DOOR CONTROL JUNCTIONFEMALE |
| OK |
|
INSPECT SLIDE DOOR CONTROL JUNCTIONMALE
Inspect the slide door control junctionmale.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE SLIDE DOOR CONTROL JUNCTIONMALE |
| OK |
|
CHECK WIRE HARNESS (SLIDE DOOR CLOSER RELAY - DOOR CONTROL RELAY)
Disconnect the B33 (M2) and slide door lock assembly connectors.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| LH side | |||||||||
|
|||||||||
| RH side | |||||||||
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
PROCEED TO NEXT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE