SLIDE DOOR CLOSER SYSTEM Slide Door Closer Motor RH Circuit

DESCRIPTION

The slide door closer relay controls the power slide door lock assembly. In response to the output signals from the switches in the power slide door lock assembly, the slide door closer drives the closer motor.

WIRING DIAGRAM

A01BG83E02

INSPECTION PROCEDURE

PROCEDURE


  1. INSPECT POWER SLIDE DOOR LOCK ASSEMBLY RH


    1. A01BFF3E02

      Inspect the slide door closer motor.


      1. Apply battery voltage and check operation of the slide door closer motor.

        Standard
        Measurement Condition Specified Condition

        Battery positive (+) → Terminal 2

        Battery negative (-) → Terminal 1

        Close (Forward)

        Battery positive (+) → Terminal 1

        Battery negative (-) → Terminal 2

        Open (Reverse)
    2. A01BB9EE01

      Inspect the pawl switch and latch switch.


      1. Measure the resistance when the switch is operated according to the value(s) in the table below.

        Standard resistance
        Pawl switch
        Tester Connection Condition Specified Condition
        8 - 9
        • Open


        • Half latch


        • Full latch

        10 kΩ or higher
        8 - 9 Unlatched Below 1 Ω
        Latch switch
        Tester Connection Condition Specified Condition
        3 - 4, 4- 8 Open Below 1 Ω
        4 - 8 Half latch Below 1 Ω
        3 - 4, 4- 8 Full latch 10 kΩ or higher
        - Over stroke 10 kΩ or higher
    3. A01BE4AE01

      Inspect the initial position switch and handle switch.


      1. Measure the resistance of the switch when the switch is operated.

        Standard resistance
        Tester Connection Condition Specified Condition
        8 - 10
        • Handle switch ON (Handle initial position)


        • Initial position switch OFF (Active lever initial position)

        10 kΩ or higher
        8 - 10
        • Handle switch OFF (As handling)


        • Initial position switch OFF (Active lever initial position)

        10 kΩ or higher
        8 - 10
        • Handle switch ON (Handle initial position)


        • Initial position switch ON (As closer operating)

        Below 1 Ω
        8 - 10
        • Handle switch OFF (As handling)


        • Initial position switch ON (As closer operating)

        10 kΩ or higher

    NG
    OK
  2. INSPECT SLIDE DOOR CONTROL JUNCTIONFEMALE


    1. A01BAYGE01

      Inspect the slide door control junctionfemale.

    2. Measure the resistance when the switch is operated according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      A - 1 Always Below 1 Ω
      E - 2 Always Below 1 Ω

    NG
    OK
  3. INSPECT SLIDE DOOR CONTROL JUNCTIONMALE


    1. A01BECAE01

      Inspect the slide door control junctionmale.

    2. Measure the resistance when the switch is operated according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      A - 1 Always Below 1 Ω
      E - 4 Always Below 1 Ω

    NG
    OK
  4. CHECK WIRE HARNESS (SLIDE DOOR CLOSER RELAY RH - DOOR CONTROL RELAY RH)


    1. A01BCGYE02

      Disconnect the M2 and slide door closer relay connectors.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      M2-4 (SW) - 7 (GND) Slide door CLOSE Below 1 Ω
      M2-5 (RLY) - 5 (+B) Slide door CLOSE Below 1 Ω
      M2-4 (SW) - Body ground Slide door OPEN 10 kΩ or higher
      M2-5 (RLY) - Body ground Slide door OPEN 10 kΩ or higher

    NG
    OK