POWER SLIDE DOOR SYSTEM Slide Door Handle Switch RH Circuit

DESCRIPTION

When the door control relay assembly receives a switch signal from the slide door lock remote control assembly RH (position switch), the door control relay assembly restricts operation of the power slide door.

WIRING DIAGRAM

Click here

INSPECTION PROCEDURE

PROCEDURE


  1. INSPECT SLIDE DOOR LOCK REMOTE CONTROL ASSEMBLY RH


    1. Remove the slide door lock remote control assembly RH Click here.

    2. A01BH6M

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 3 Handle in initial position 10 kΩ or higher
      2 - 3
      1 - 3 Handle pulled Below 1 Ω
      2 - 3

    NG
    OK
  2. INSPECT SLIDE DOOR LOCK REMOTE CONTROL ASSEMBLY RH


    1. A01BBFWE03

      Remove the slide door lock remote control assembly RH Click here.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 4 Lock 10 kΩ or higher
      1 - 4 Unlock Below 1 Ω

    NG
    OK
  3. INSPECT REAR DOOR WIRE RH


    1. A01BDMZE01
      Text in Illustration
      *a

      Rear Door Wire RH

      (Door Control Relay Assembly Side)

      *b

      Rear Door Wire RH

      (Slide Door Lock Remote Control Assembly RH Side)

      Disconnect the ci1 and fc1 rear door wire RH connectors.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A-8 - B-11 Always Below 1 Ω
      A-12 - B-17 Always Below 1 Ω
      A-9 - B-4 Always Below 1 Ω
      A-10 - B-16 Always Below 1 Ω

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (DOOR CONTROL RELAY ASSEMBLY - SLIDE DOOR LOCK REMOTE CONTROL ASSEMBLY RH)


    1. Disconnect the I4 door control relay assembly connector.

    2. Disconnect the f4 and f5 slide door lock remote control assembly RH connectors.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      I4-8 (MPX1) - f4-1 Always Below 1 Ω
      I4-20 (MPX2) - f4-2 Always Below 1 Ω
      I4-13 (OSG) - f4-3 Always Below 1 Ω
      I4-22 (DLSW) - f5-4 Always Below 1 Ω
      I4-13 (OSG) - f5-1 Always Below 1 Ω
      I4-8 (MPX1) or f4-1 - Body ground Always 10 kΩ or higher
      I4-20 (MPX2) or f4-2 - Body ground Always 10 kΩ or higher
      I4-13 (OSG) or f4-3 - Body ground Always 10 kΩ or higher
      I4-22 (DLSW) or f5-4 - Body ground Always 10 kΩ or higher
      I4-13 (OSG) or f5-1 - Body ground Always 10 kΩ or higher

    NG
    OK