DISCONNECT CABLE FROM BATTERY NEGATIVE TERMINAL
CAUTION:
Wait for 90 seconds after disconnecting the cable to prevent the airbag working.
REMOVE INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY NO.1
Using a moulding remover, disengage the 3 claws and remove the instrument cluster finish panel No.1 garnish.
REMOVE AIR BAG SENSOR ASSEMBLY CENTER
Disconnect the airbag connectors, as shown in the illustration.
Remove the 3 bolts and center airbag sensor.