FRONT BLOWER RESISTOR INSPECTION


  1. INSPECT FRONT BLOWER RESISTOR (for LHD)


    1. A01BBHWE02

      Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      1 - 4 Always 3.12 to 3.60 Ω
      1 - 2 Always 1.45 to 1.67 Ω
      1 - 3 Always 0.52 to 0.60 Ω

      If the result is not as specified, replace the front blower resistor.

  2. INSPECT FRONT BLOWER RESISTOR (for RHD)


    1. A01BBHWE02

      Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      1 - 4 Always 3.12 to 3.60 Ω
      3 - 4 Always 1.45 to 1.67 Ω
      2 - 4 Always 0.52 to 0.60 Ω

      If the result is not as specified, replace the front blower resistor.