FRONT BLOWER MOTOR INSPECTION


  1. INSPECT FRONT BLOWER MOTOR (for LHD)


    1. A01BE8UE01

      Connect the positive (+) lead from the battery to terminal 2 and the negative (-) lead to terminal 1, and check that the motor operates smoothly.

      OK
      The blower motor operates smoothly.

      If the result is not as specified, replace the blower motor.

  2. INSPECT FRONT BLOWER MOTOR (for RHD)


    1. A01BAA3E01

      Connect the positive (+) lead from the battery to terminal 2 and the negative (-) lead to terminal 1, and check that the motor operates smoothly.

      OK
      The blower motor operates smoothly.

      If the result is not as specified, replace the blower motor.