AIR CONDITIONING SYSTEM Warm Air does not Flow Immediately after Engine Start with Temperature Control Dial at Max. Hot

CAUTION / NOTICE / HINT

Tech Tips

This troubleshooting flowchart is used only for 1KD-FTV, 2KD-FTV engine models.

INSPECTION PROCEDURE

PROCEDURE


  1. INSPECT FUSE (PTC1, PTC2)


    NG
    OK
  2. INSPECT RELAY


    1. Inspect the HTR relay Click here.

    2. Inspect the PTC relay Click here.


    NG
    OK
  3. INSPECT AIR MIX DAMPER CONTROL SWITCH

    Click here


    NG
    OK
  4. INSPECT AMBIENT TEMPERATURE SENSOR

    Click here


    NG
    OK
  5. INSPECT QUICK HEATER ASSEMBLY

    Click here


    NG
    OK
  6. CHECK HARNESS OR CONNECTOR


    1. Disconnect the cooler stabilizer amplifier connector.

    2. Disconnect the air mix damper control switch connector.

    3. Disconnect the ambient temperature sensor connector.

    4. Disconnect the quick heater connector

    5. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      FRBV (H18-22) - B (H17-8) Always 10 kΩ or higher
      MHSW (H18-38) - L (H17-6) Always 10 kΩ or higher
      SG-1 (H18-12) - B (A14-2) Always 10 kΩ or higher
      TAM (H18-25) - B (A14-1) Always 10 kΩ or higher
      FRBV (H18-22) - Body ground Always Below 1 Ω
      MHSW (H18-38) - Body ground Always Below 1 Ω
      SG-1 (H18-12) - Body ground Always Below 1 Ω
      TAM (H18-25) - Body ground Always Below 1 Ω
      PTC (H18-2) - Body ground*2 Always Below 1 Ω
      PTCL (H18-3) - Body ground Always Below 1 Ω
      Result
      Result Proceed to
      OK (w/o HOT Gas Heater) A
      OK (w/ HOT Gas Heater) B
      NG C

    B
    C
    A
  7. INSPECT HEATER SWITCH ASSEMBLY

    Click here


    NG
    OK
  8. CHECK MAGNET VALVE


    1. Inspect the magnet valve under Test Mode.


      1. Turn the ignition switch to ON.

      2. Set the temperature so that the setting is not MAX HOT.

      3. Turn the ignition switch off, start the engine, and then press the A/C switch twice within 3 seconds.

      OK
      A magnet valve operation sound is heard.

      Tech Tips

      Test Mode ends when the temperature is set to MAX HOT or the A/C switch is pressed.


    NG
    OK
  9. INSPECT REFRIGERANT VOLUME

    Click here


    NG
    OK
  10. INSPECT MAGNET VALVE

    Click here


    NG
    OK
  11. CHECK HARNESS OR CONNECTOR


    1. Disconnect the cooler stabilizer amplifier connector.

    2. Disconnect the magnet valve connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      IG+ (H18-20) - IG (A28-1) Always 10 kΩ or higher
      HGMG (H18-17) - MGV (A28-2) Always 10 kΩ or higher
      IG+ (H18-20) - Body ground Always Below 1 Ω
      HGMG (H18-17) - Body ground*2 Always Below 1 Ω

    NG
    OK