LOAD SENSING PROPORTIONING VALVE INSPECTION


  1. INSPECT LOAD SENSING PROPORTIONING VALVE ASSEMBLY


    1. A01BCLI

      Inspect contact surface wear between the control valve piston and spring.

      Standard
      0.7 mm (0.028 in.)

      Note

      Do not disassemble the load sensing proportioning valve assembly.