LOAD SENSING PROPORTIONING VALVE DISASSEMBLY


  1. REMOVE LOAD SENSING PROPORTIONING VALVE ASSEMBLY


    1. A01BGM2E01

      Place the load sensing valve in the vise.

    2. Remove the nut while holding the bolt.

    3. Remove the 2 nuts, the valve set plate and the valve bracket.

    4. A01BCTW

      Remove the clip and the load sensing proportioning valve assembly.

  2. REMOVE LOAD SENSING SPRING BUSH & BOOT KIT


    1. A01BBA8

      Place the load sensing spring bracket in the vise.

    2. Remove the bolt, load sensing spring bracket, collar and the 2 bushs from the spring shackle No.2.

    3. A01BDUGE01

      Remove the 2 plate washers, spring washer, spring shackle No.1, bolt, and nut.

    4. A01BCCG

      Remove the lock nut, spring shackle No.1, plate washer, and nut from the spring shackle No.2.

    5. A01BI50E01

      Remove the following parts from the load sensing spring.

      Symbol Name Quantity
      A Load sensing spring bush No.1 2
      B Load sensing spring bush No.2 2
      C Load sensing spring collar 1
      D Load sensing valve boot 1
      E Load sensing spring boot 1
      F Load sensing spring washer 2
      G Load sensing spring collar 1