2KD-FTV VACUUM PUMP ON-VEHICLE INSPECTION


  1. OPERATION CHECK


    1. Disconnect the vacuum hose.

    2. Connect the vacuum gauge to the vacuum pump.

    3. Start the engine.

    4. A01BBFNE02

      Measure the vacuum with the engine idling.

      Standard
      More than 650 mmHg (86.7 kPa).