STARTING SYSTEM INSPECTION


  1. INSPECT STARTER ASSEMBLY

    Note

    The following tests must be performed within 3 to 5 seconds to prevent the coil from burning out.


    1. A01BGKFE01

      Perform the pull-in test.


      1. Disconnect the field coil lead wire from terminal C.

      2. A01BCTME01

        Connect the battery to the magnetic switch as shown in the illustration. Check that the clutch pinion gear is extended.

    2. A01BCDHE01

      Perform the hold test.


      1. Disconnect the negative (-) lead from terminal C while sustaining the above condition (a). Check that the pinion gear remains extended.

    3. A01BGLTE01

      Check the return operation.


      1. Disconnect the negative (-) lead from the starter body. Check that the clutch pinion gear returns inward.

    4. A01BGKF

      Perform the operation test without any load.


      1. Connect the field coil lead wire to terminal C.

        Torque:
        10 N*m  { 102 kgf*cm, 7.4 ft.*lbf }
    5. A01BF0FE01

      Clamp the starter in a vise.

    6. Connect the battery and ammeter to the starter as shown in the illustration.

    7. Check that the ammeter indicates the specified current.

      Specified current
      90 A or less at 11.5 V