STARTER (for 2.2 kW Type) REMOVAL


  1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

  2. DISCONNECT TRANSMISSION CONTROL CABLE ASSEMBLY (for Automatic Transmission)


    1. A01BDE0E03

      Remove the nut and disconnect the transmission control cable assembly from the transmission control shaft lever assembly.

    2. Remove the clip and disconnect the transmission control cable assembly from the No. 1 transmission control cable bracket.

  3. REMOVE NO. 1 TRANSMISSION CONTROL CABLE BRACKET (for Automatic Transmission)


    1. A01BFFD

      Remove the 2 bolts and the No. 1 transmission control cable bracket from the automatic transmission housing.

  4. REMOVE STARTER ASSEMBLY


    1. A01BG1IE01

      for Wide Body:

      Remove the bolt and ground cable.

    2. A01BBES

      Open the terminal cap.

    3. Remove the nut and disconnect the wire harness from terminal 30.

    4. Disconnect the terminal 50 connector from the starter.

    5. A01BCBG

      for Automatic Transmission:


      1. Remove the bolt, 2 nuts and starter.

    6. A01BEVC

      for Manual Transmission:


      1. Remove the bolt, nut and starter.