INSPECT COOLING FAN RELAY
Check the resistance.
Using an ohmmeter, measure the resistance between the terminals.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the relay.
INSPECT COOLING FAN MOTOR
Check that the motor turns smoothly when the battery is connected to the fan motor connector.
Using an ammeter, measure the current while the motor is turning.
| Standard |
|---|
| 17 to 23 A (20°C (68°F)) at 12 V |
ENGINE COOLANT TEMPERATURE SENSOR
Partially soak the sensor in the water and warm up the water.
Measure the resistance between the terminals.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the sensor.
Note
When checking the sensor in the water, keep the terminals dry. After the check, wipe the sensor dry.