INSPECT VACUUM SWITCHING VALVE ASSEMBLY NO.1 (EVAP VSV)
Check the resistance.
Using an ohmmeter, measure the resistance between the terminals.
| Standard resistance | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the vacuum switching valve assembly No.1.
Check the vacuum switching valve No.1 for ground.
Using an ohmmeter, check the resistance between each terminal and the body.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the vacuum switching valve assembly No.1.
Check the operation.
Check that air does not flow from port E to port F.
If the operation is not as specified, replace the vacuum switching valve assembly No.1.
Apply battery voltage across the terminals.
Check that air flows from port E to port F.
If the operation is not as specified, replace the vacuum switching valve assembly No.1.