INSPECT OXYGEN SENSOR
Inspect the sensor heater.
Measure the resistance between terminals 1 (HT) and 2 (+B) of the sensor.
| Standard resistance |
|---|
| 11 to 16 Ω at 20°C (68°F) |
If the result is not as specified, replace the oxygen sensor.
Measure the resistance between terminals 1 (HT) and 4 (E1) of the sensor.
| Standard resistance |
|---|
| 10 kΩ or higher |
If the result is not as specified, replace the oxygen sensor.